                       INSTALLATION AND STARTUP


                       Chapter 1 Introduction


                       UL Information

                       This applies when an optional door controller is installed




                              To reduce the risk of severe injury or death to persons all material and
                              instructions intended for Belanger system and door operator shall be
                              read and comprehended. If material/instruction are not present, they
                              must be obtained prior to beginning installation/modification.

                              The Door Control System shall not be installed at locations that don’t
                              provide a Service entrance. The service opening shall be labeled as an
                              exit and placards installed on vertical door indicating no pedestrians.

                              The Belanger system is not intended for use as source of preventing
                              injury to persons, nor is it intended for entrapment or obstruction
                              protection as described in UL 325. This equipment is intended to
                              enhance the system by signaling the doors desired position, but be
                              overridden by operator’s safety features. The operator that is in direct
                              control of the door must independently provide entrapment protection
                              in accordance with UL325. Installation of the Belanger system shall not
                              interfere with primary of secondary entrapment protection, nor interfere
                              with any provided safety features of the door operator.

                              The installer shall evaluate the existing/new operator requirements for
                              maintaining UL325 compliance, Examples include loss of being in
                              accordance when parallel connections are made to up/down buttons, or
                              loss of being in accordance when upward motion brings door within 2
                              feet of a solid object, etc.