Page 10 - Tunnel Support Components
P. 10

TUNNEL SUPPORT COMPONENTS


             Introduction


             Basic Overview

                 The components covered in this manual are typically the most critical parts of the Belanger, Inc. Car
                 Wash System, it is imperative that you understand the concepts used in their designs and they MUST be
                 installed correctly.


             Component Placement
                    Note:  See site-specific prints and drawings for dimensions and actual tunnel placement of all
                           components.
                 Traditionally it is advised to locate and install the Motor Starter Panel and the Output Controller first so
                 that the utility contractors can get their work out of the way.
                 The Motor Starter Panel and the Output Controller are the “BRAINS” of the system.  They  do  the
                 thinking. They house the following components:
                  •   Motor Starters           •  Main Disconnect          •   System Output Boards
                 The Hydraulic Unit and Pneumatic Panels  are  the  “HEART” of the system.  They pump life into the
                 tunnel components. The Pneumatic Panels should be mounted on the wall very close by.

                 All of the above components are designed to be installed in a traditional “Back Room” and comes with a
                 standard utility package that  will accommodate most back rooms. Your VAR  can  acquire  any
                 additionally required utility materials.

                                                  CAUTION

                     No communication cables are to run through the same conduit as any 3 phase
                                           wires due to possible interference.

                                                  CAUTION


                    It is recommended that a licensed electrician is contracted to perform all electrical installations.



                              Disconnect and lockout electrical power before servicing any equipment!




                            Always wear safety glasses when performing maintenance on any equipment.


                    Note:  See  Provided  Prints  for  details on all electrical, hydraulic and pneumatic connections
                           (incoming and outgoing).












              8           Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681          1MANUL760
   5   6   7   8   9   10   11   12   13   14   15