Page 12 - Tunnel Support Components
P. 12

TUNNEL SUPPORT COMPONENTS


             Installation


             Hydraulic Unit Overview

                 The Hydraulic Supply Units come with a premium Variable Volume Pumps. When adjusting the speed
                 of a piece of equipment, the speed of other components will not be affected unless the maximum supply
                 capabilities are exceeded. The pump throttles itself to only displace the required amount of oil.
                                                  CAUTION


                      This unit should NEVER be used to run only a Conveyor. This will cause overheating and
                                                      damage the unit.
                 There  are  three  available  Hydraulic Supply Units, the 5HP unit, 10HP unit and the 20HP unit. The
                 number of components determines the size required in the system and/or the  specifics  of  those
                 components.
                 The  5HP  Hydraulic  Unit is a fixed displacement and should be purchased when extra capacity is
                 required. The Enduro Class 60 comes standard with a 10HP Unit and the Pro Class100 comes with a
                 20HP unit.
                 It  may become necessary to upgrade your system from a 10HP to a 20HP hydraulic unit or add an
                 auxiliary hydraulic unit if you add components to your system at a later date. If you have questions about
                 your systems hydraulic capacity, consult your local VAR.
                 Of the two variable displacement units there are some distinct differences. The 20HP unit has larger feed
                 and return manifolds.
                                                  CAUTION


                      Do Not exceed 1000 PSI operating pressure on ANY systems Hydraulic Unit. Failure to stay
                                           within limits will trip the Motor Starters.


                Placement
                 Place your Hydraulic Unit in the desired location and bolt it to the floor. Be sure it is in a safe and dry
                 environment.