Page 21 - Prep Jet System
P. 21

PREP JET SYSTEM



                       Maintenance


                       Routine Procedures
                       Weekly
                           Check the oil level and the condition of the oil.

                           Check general operating condition. Pump should be run smooth with no adverse noises coming from it.  If pump runs
                           rough or makes strange noises, or if there is a drop in pressure, refer to Trouble Shooting section below.


                       Trouble Shooting

                                   Problem                       Cause                        Solution
                         Pump does not run             •   Blown fuses              •   Replace fuses
                                                       •   Overloads tripped        •   Reset overload switches
                                                       •   Faulty starting circuit   •   Replace starting circuit
                                                       •   Faulty motor             •   Replace motor
                                                       •   Air in water supply line   •   Purge water lines
                                                       •   Inadequate water level in tank   •   Fill supply tank and confirm that the
                                                                                        Hydro  Minder™  valve  is
                                                                                        functioning properly
                         Drop in volume or pressure    •   Air leak in suction line    •   Replace suction lines
                                                       •   Worn unloader valve      •   Replace unloader valve
                                                       •   Empty supply tank        •   Fill supply tank and confirm that the
                                                                                        Hydro  Minder™  valve  is
                                                                                        functioning properly







































                        1MANUL603                             Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681                        19