Page 31 - DuraFlo™ 18 GPM Pump Station
P. 31
DURAFLO™ 18 GPM PUMPING STATIONS
Maintenance
Pumping Station Float Valve Seal Replacement Kit (#105884)
Removing the Existing Stem Assembly
3) Remove the valve from the Bulkhead fitting on the tank.
4) Remove the two upper pins and Cotter Pins. Remove the pin that connects the Link to the
Lever and the pin that connects the Lift to the Lever.
Upper Pins Lever
Cotter Pins
Lift
Link
5) Loosen the Jam Nut and remove the Lift from the Stem, then remove the Jam Nut from the
Stem.
Lift
Loosen this Jam Nut Stem
6) Loosen the Lock Nut from the Bonnet and remove the nut and the Swivel Yoke.
Lock Nut
Swivel Yoke
Bonnet
Loosen this Lock Nut
1MANUL375 Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470* Ph (248) 349-7010 * Fax (248) 380-9681 27