JET PUMPING STATION


            Maintenance


            General

                                                   CAUTION


                                  The following steps are CRITICAL TO PROPER OPERATION!!

            1)  After the first eight hours of operation, remove the belt guard and retighten the bolts which secure
               the pulleys to the motor and pump. Check the belt tension at this time.
                                                   CAUTION


                      Over-tightening drive belts can damage pump and motor bearings. This is not covered by the
                               warranty. Belts should deflect 1/4” to 3/8” when pressed on from above.

            2)  After the first 100 hours of operation change the oil in the Wanner H-25 Pump. Replace with 10W30
               Hydra-Oil available from Wanner Engineering. Oil is to be changed every 500 hours of operation
               thereafter.
                                                   CAUTION

                                         Do not rotate pump when oil reservoir is empty.


            Belt guard removal










                                                                             Remove the
                                                                             four bolts
                                                                             from below   Loosen, but
                                                                             (typical)   do not
                                                                                        remove two
                                                                                        bolts (typical)




























              20          Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL361