Page 22 - Jet Pumping Station
P. 22
JET PUMPING STATION
Maintenance
General
CAUTION
The following steps are CRITICAL TO PROPER OPERATION!!
1) After the first eight hours of operation, remove the belt guard and retighten the bolts which secure
the pulleys to the motor and pump. Check the belt tension at this time.
CAUTION
Over-tightening drive belts can damage pump and motor bearings. This is not covered by the
warranty. Belts should deflect 1/4” to 3/8” when pressed on from above.
2) After the first 100 hours of operation change the oil in the Wanner H-25 Pump. Replace with 10W30
Hydra-Oil available from Wanner Engineering. Oil is to be changed every 500 hours of operation
thereafter.
CAUTION
Do not rotate pump when oil reservoir is empty.
Belt guard removal
Remove the
four bolts
from below Loosen, but
(typical) do not
remove two
bolts (typical)
20 Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL361