Page 24 - Jet Pumping Station
P. 24
JET PUMPING STATION
Maintenance
Trouble Shooting Guide
Problem Cause Solution
Pump does not run • Blown Fuses • Replace fuses
• Overloads tripped • Reset overload switch
(located on Customer supplied Motor Starter)
• Faulty car wash programmer
• Check programmer for damage
• Faulty motor
• Replace motor (Part No. 1MOTOR-EL978)
• Faulty pump
• Replace pump (Part No. 1PUMP937)
Pump runs rough • Fluid too hot • Shut off machine to allow fluid to cool off
• Air in water supply line • Purge airlines to remove bubbles
• Excessive turbulence or vibration in tank • Make sure tank is sitting level. Check for worn
leveling feet (Part No. 1MOUNT-PS750)
• Inadequate fluid level in tank
• Increase fluid level
Drop in volume or • Air leak in suction line • Replace suction lines
pressure • Worn un-loader valve • Replace un-loader valve (Part No. 1VALVE-WA125)
• Empty supply tank • Refill fluid supply tank
• Slipping drive belt • Tighten or replace belt (Part No. 1BELT500, Generic
#B52)
losing oil but do not • One of the diaphragms inside the pump • Replace diaphragm (Refer to Wanner Service
see any external may be damaged Section)
leakage
CAUTION
When DO NOT OPERATE THE PUMP WITH A DAMAGED DIAPHRAGM.