Page 23 - Jet Pumping Station
P. 23

JET PUMPING STATION


                    Maintenance


                    Routine Procedures

                       Daily
                        •   Check the oil level and the condition of the oil.
                        •   Check hoses for punctures .

                        •   Check general operating condition. Pump should run smooth with no adverse noises coming from it. If
                            pump runs rough or makes strange noises, or if there is a drop in pressure, refer to Wanner Trouble
                            Shooting Section.

                        •   Check operation of float valve.
                        •   Start every wash day with a “Test Wash” to insure proper operation of all equipment.
                        •   Check overall performance for any abnormalities on the first few vehicles washed each day.

                        •   Check for water and chemical leaks after equipment is turned off.
                       Weekly
                        •   Check  belt  tension. If belts are worn or have a  tendency to slip, replace belts (Part No. 1BELT500,
                            Generic #B52).

                        •   Check all mixing tanks for sludge buildup or any other contaminants on the bottom. If too much sediment
                            is evident, drain tank and clean.
                        •   Weekly cleanings of the frame should also be done. Use a good degrimer such as Tide laundry detergent
                            with hot water.

                           Note:  OVER TIGHTENING BELTS VOIDS WARRANTY!
                        •   Check condition of vibration isolators. If they are worn or sagging, replace them (Part No. 1MOUNT-
                            PS500).
                           Note:  All four isolators must be replaced at the same time .

                        •   Drain and wipe down interior of tank. This will prevent buildup of contaminants.
































                      1MANUL361          Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681         21
   18   19   20   21   22   23   24   25   26   27   28