THE NEON STIK™


             Installation


             Utility Connection: Flasher Unit not Desired

                    1)  Electrical conduits between electrical enclosures.
                    2)  All wires are #12AWG except the control wires to the relay.
                    3)  User must supply from existing electrical  power  panel,  a supply source of 120VAC through a
                       20Amp dedicated breaker.

                                                  CAUTION

                                      No other connection from this breaker.

                    4)  User must supply a 120VAC signal from existing car wash control panel such  as  “Datatrax™”,
                       “Compuwash™” or CCU.
                    5)  Electrical connections at The Neon Stik™ are made using wire nuts and covered with electrical
                       tape.
                    6)  User supplied relay. Contacts must have a 15Amp rating.
































                             Connections
                     Conduit Side       Arch  Side
                      Black L1     to    Black L1

                      White L2     to    White L2
                      Green  Gnd   to    Green Gnd


                                                  CAUTION

                     If relay is NOT in the Belanger, Inc. CCU, it MUST be housed in a “Water-Tight” enclosure
                                                  and in the “Back Room”.