                       Installation


                       Assembly

                              1)  Remove all shipping materials from the Wind Door (e.g. steel bands and wire ties).
                              2)  Locate head frame assembly; determine the entrance side from the exit side (cylinders should face
                                 inside of tunnel so that  doors  open to the inside of tunnel unless wind door is mounted on the
                                 outside of the building whereas the doors will open toward the outside of building).
                              3)  Locate accessory box, and the two support legs.
                              4)  Using a fork lift and clamps, raise the head frame assembly above the height of the legs.
                                                             CAUTION


                              Be sure to clamp equipment to the forks of the fork lift. Do not stand under load
                                                        while fork lift is in operation!
                              5)  Position the head frame assembly and legs in their approximate location in the tunnel.
                              6)  Using the 1/2-13 x 1-1/4” bolts and the 1/2-13 regular nuts provided, bolt the legs to the main head
                                 assembly making sure that the Velcro faces the cylinder side.



                                                 Secure bolts
                                                 on both sides





                                                                     Secure bolts
                                                                     on both sides






                              7)  Position and lower the completed assembly into its exact location (to the top of the entrance or exit
                                 door opening and center it to the center line of the  door opening, or to the  center line of the
                                 equipment).