            Installation


            Lagging Frame to the Floor

                   1)  Once the equipment is properly positioned, check for level and plumb on all dimensions.
                   2)  Shim the Wind Door™ appropriately (shims not provided), drill and lag the Wind Door to the floor
                       using the 1/2-13 x 3-1/2” cement quick lag bolts provided.
                   Note:  There are a total of four 1/2” lag bolts provided (two for each leg). Install the lag bolts
                          diagonally on the detail plate.


                                                  CAUTION


                     Belanger, Inc. does not recommend the use of a Clear Wind Seal Door at exit end of facility
                    where no employee is present to assist door opening if failure occurs. This may cause damage to
                                                 vehicle and/or equipment.