Page 22 - Wind Doors
P. 22

WINDDOOR


            Installation


            Photo Eye Dip Switch Programming




                                                                             MODEL NUMBER
                    SWITCH PROGRAMMING
                                     SWITCH                               CL3RA        CL3RB
                        = OFF  = ON  LOCATION
                                                                          CL5RA        CL5RB
                                                                            HOOKUP DIAGRAM
                                                                                            + 15V
                                                                        250VAC
                                                                        SPDT 5A             INPUT
                                                                        RELAY
                                                                        OUTPUT              COM
                      N/C OUTPUT =  N/O OUTPUT =
                     .15 SEC.  .15 SEC.  .15 SEC.
                     MAX. TIME  MAX. TIME  MAX. TIME  SWITCH            SUPPLY              INV
                                                                         AC
                                                                                            AUX
                                                                         4 VA
                      ON/OFF  ON DELAY  OFF DELAY  BOTH DELAYS  1-SHOT  DELAYED 1-SHOT  LIMIT  REPEAT CYCLE  AC LATCH  DC LATCH  DELAY = LATCH  LIMIT = LATCH  LOCATION  50/60 HZ  = input
                                                                        AC Supply: RA=110V, RB=220V
                                                                        Pin 3: Sensor supply; 50ma max.
                                                                        Pin 2: Sink to Common
                                                                        when pin 11 is jumpered to pin 10)
                     NOTE: when switches 1 - 7 are programmed for       (Release from Common  = input
                     ON/OFF logic, switches 9 & 10 are disabled.

                   Note:  Programming set at the factory.










































             20        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681       1MANUL874