               Vinyl Panels
               Problem                     Cause                       Solution
               •   The door will not open   •   Bad photo eye          •   See photo eye trouble shooting
                                           •   Bad limit switch        •   See limit switch trouble shooting
                                           •   Bad rollers             •   Check rollers for wear (flat spots)
                                           •   Bi-fold arms are not level   •   Check hinges
                                           •   Valve is not hooked up   •   Refer to schematics
                                              properly                 •   Replace valve or coil
                                           •   Valve is bad            •   Replace cylinder (see
                                           •   Cylinder rod is bent       replacement parts page)
                                           •   Frozen cylinder         •   Thaw cylinder out, drain air
                                           •   Lack of air pressure       system of moisture
                                                                       •   Check regulator and main air
                                                                          supply
               •   Door slams closed       •   Needle leak flow control   •   Adjust needle valves
                                              improperly adjusted      •   Replace the shock
                                           •   Shock has gone bad      •   Reduce air pressure at regulator
                                           •   Excessive air pressure
               •   Cylinders are freezing up   •   Cold weather        •   Wrap the cylinders up with heat
                                           •   Excessive water in the air   tape
                                              lines                    •   Thaw cylinder out
                                                                       •   Drain air system of moisture
               •   Door won’t open or close at   •   One of the bleed-off valves   •   There are two bleed-off valves at
                  the correct speed (too fast, or   needs to be adjusted   the bottom of the double
                  too slow)                •   Air pressure set wrong     solenoid, Adjust as follows:
                                                                          1)  To open faster: Loosen left valve
                                                                          2)  To open slower: Tighten left valve
                                                                          3)  To close  faster: Loosen right valve
                                                                          4)  To close slower: Tighten right valve
                                                                       •   Adjust needle valves





























             22        Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681       1MANUL874