Page 29 - MixStir® Chemical Delivery System
P. 29

MIXSTIR® CHEMICAL DELIVERY SYSTEM

                       Operation


                       Chemical Dilution Ratio

                       The following experimental procedures may be used as the basis to figure how much chemical is
                       being applied to each vehicle.

                          Note:  As long as your supply water pressure is above 25 PSI your results will be consistent
                       The following items are required to perform the procedure.

                           Small Measuring Beaker      Large Measuring Container
                           Protective Gloves           Safety Glasses
                          1)  Close the water feed ball valve to an initially closed position.
                          2)  Fill the smaller Measuring Beaker with the chemical in question. Make a note of how much
                              is initially in the beaker.
                          3)  Run chemical draw tube to the smaller measuring beaker.
                          4)  SLOWLY open the water feed ball valve to draw the measured chemical up the tube. When
                              the chemical is just about to reach the Hydro-minder close the water ball valve.
                          5)  Position the large Measuring Container to receive the HydroMinder’s output feed.
                          6)  Paying close attention to the chemical line, open the water feed ball valve to activate the
                              HydroMinder.
                          7)  Stop the HydroMinder when either all the chemical has been drawn, or your large Measuring
                              Container is at its maximum.
                          8)  If there is any unused chemical, drain it back into the small measuring beaker and note how
                              much chemical is left.
                              This should be enough information to determine the mixing ratio you are achieving.
                              Use the following formula for the ratio calculation.
                              Output Feed – Chemical Used   /   Chemical Used: 1