Page 52 - QuickFire® Wrap Around Mix & Match
P. 52
QUICKFIRE® WRAP AROUND
Installation
Utility Connections for Side Wheels: Electric
4) Slide the two clamps over the conduit in the orientation shown. Secure the conduit into the fitting of
the electrical enclosure. Fasten the loop clamps into the threaded holes as shown below.
Secure the Loop
Clamps
Slide Clamps
Over Hose
5) Repeat this process on the other side
Water Manifolds
1) Locate 110” black conduit with18FT of wire, the 60” black water hose, the water manifold and 12
rubber grommets. Also fasteners (8).
Black Water Hose 2-Piece Utility
Conduit (110”) Water Manifold Grommet (uncut)
(60”) Clamp
2) Cut four of the grommets in half, creating eight pieces. Cut a split down the side of the remaining
eight grommets. See images below.
1/2 Grommet Split Grommet
48 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL825