Page 14 - Auto Fluid Injection System (AFIS)
P. 14

AUTO FLUID INJECTION SYSTEM (AFIS)



             Maintenance


             Trouble Shooting

                       Problem                        Cause                        Solution
               No water at the equipment   •   No water supply            •   Check inlet water supply
                                           •   No voltage at the solenoid   •   Check the carwash controller
                                                                          •   Check the voltage source
               No chemical delivery        •   Pressure relief/priming valve   •   Close the relief/priming valve
                                               open                       •   Check feed adjustment
                                           •   Feed adjustment not set correctly   •   Check the carwash controller
                                           •   No voltage at the injection pump   •   Check the voltage source
                                           •   Clogged or faulty fitting(s)   •   Clean or replace the foot valve,
                                           •   Faulty diaphragm in the pump   injection fitting or other fittings in
                                           •   Faulty pump                   the system
                                                                          •   Replace the diaphragm
                                                                          •   Replace the dump




















































             12         Belanger , Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681         1MANUL006