TOP WHEEL Mix and Match
Specifications
Requirements
Physical
Tunnel space required 114”
Unit height 140”
Unit width 146”
Utility
Electrical 3 phase, 1HP motor standard
3 phase, 2HP motor for Brush Application
110V for Retract Option
Hydraulic 6 GPM @ 900 PSI
Pneumatic .3 CFM @ 90 PSI minimum 120 PSI maximum
Water (1) 3/4” hose @ 4 GPM @ 40 PSI
Output
Physical
Vehicle clearance, height 90”
DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
EQUIPMENT!
Always wear safety glasses when performing maintenance on any equipment
It is recommended that a licensed electrician is contracted to perform all electrical installations.
YOUR HYDRAULIC SYSTEM MUST BE CAPABLE OF ADJUSTMENT TO 116 RPM AT
900 PSI (62.1 BAR) WHILE LOADED AGAINST VEHICLE. PLEASE VERIFY YOUR
SYSTEMS CAPABILITY TO MEET THESE SETTING WHILE RUNNING A VEHICLE
PRIOR TO INSTALLING PIECE OF EQUIPMENT
A compressed Air System should be set correctly to support 90 PSI necessary to operate
equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger
specified equipment.
1MANUL749 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 9