Page 52 - Top Wheel Mix & Match
P. 52
TOP WHEEL Mix and Match
Maintenance
General Repairs
Torque Plate and Electric Motor Replacement
DANGER
DISCONNECT MAIN POWER SUPPLY PRIOR TO SERVICING
OR MAINTAINING EQUIPMENT
Remove Motor Gearbox assembly
1) To ensure safety we recommend following the OSHA Lockout / Tagout procedure prior to performing service or
maintenance on machinery and equipment.
If the assembly does not have a cover proceed to step 3
2) Remove both Phillip head screws, to allow plastic cover to be removed from cover base.
Remove Phillip Head Screws
3) Verify power has been removed from circuit by checking voltage at the junction box with a multi-meter to confirm
no power is being supplied to the equipment.
4) Remove the junction box cover to gain access to motor wiring.
5) Remove the nuts to release wiring from the terminal block.
6) Verify wiring has been tagged for proper terminal connections if not previously identified at original installation.
7) Disconnect wiring leads, and remove electric feed
Wires are located behind the terminal
strip and will need to be pulled
through the cord grip fitting on the
bottom of the junction box.
The cord grip will need to be
loosened, or removed so that
the wiring can be pulled down
through the cover base if
equipped.
48 Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681 1MANUL749