                    Problem                  Cause                            Solution

               Fan:                    No power                  Check power coming to Fan
                   Not Working         Incorrect wire connections      Check  to  make  sure  the  wire  connections  are
                                                                   correct in the Fan Enclosure
                                       Controller Program
                                                                  Verify that the Controller has been programmed
                                                                   properly
               Fan:                    Incorrect wire connections      Check  to  make  sure  the  wire  connections  are
                   Incorrect Speed      Controller Program        correct in the Fan Enclosure
                                                                  Verify that the Controller has been programmed
                                                                   properly
               Chemical Delivery:      Clogged foot valve on suction      Clean or replace foot valve
                    No chemical         line                      Fill storage tank
                                       Empty storage tank
                                                                  Prime chemical pump
                                       Chemical  pump  has  lost
                                        prime                     Check for proper operating voltage
                                       Solenoid valve not energized
               Chemical Delivery:          Nozzles clogged       Verify Spray Nozzles are pointing downward and
                   Pulsating or        Dirt in solenoid valve     toward the center finger of the Tri Nozzles
                    Weak Spray                                    Remove  Bayonet  Nozzle  from  Tri  Nozzle  and
                                       Kink in hose
                                                                   clean with thin wire
                                       Inadequate water pressure
                                                                  Remove Bayonet Nozzle from Tri Nozzle, verify
                                                                   arrow  on  check  vavle  is  pointing  toward  the
                                                                   spray nozzle
                                                                  Disassemble Bayonet Nozzle clean components
                                                                   and reassemble with pipe dope
                                                                  Disassemble and clean solenoid valve
                                                                  Remove any kinks from hose
                                                                  Open water valve to fullest
                                                                  Call  Distributor  for  advice  on  installing  booster
                                                                   pump
               Wall Washers:           Incorrect wire connections      Check  electrical  connections  at  Wall  Washer
                   Not Turning On      Controller Program         and Air Plenum
                                                                  Verify  wire  connections  in  24vdc  Power  Pupply
                                                                   Enclosure
                                                                  Check Main power coming into the 24vdc Power
                                                                   Supply Enclosure
                                                                  Verify that the Controller has been programmed
                                                                   properly
               Wall Washers:           Controller Program        Verify that the Controller has been programmed
                   Not Turning Off                                 properly

               Wall Washers:           Not adjusted when installed      Manually rotate Wall Washers on Pivot Brackets
                   Incorrect Position                              to direct light onto bubbles and vehicle