Page 85 - 2018 National Home Improvement
P. 85

2018 National Home Improvement Estimator, All Rights Reserved                                    Page 67



              20" centers (.45 BF per SF)                   B1@.020   SF      0.29       0.73       1.02
              24" centers (.37 BF per SF)                   B1@.016   SF      0.24       0.58       0.83
              Add for each corner or partition              B1@.083   Ea     11.21       3.03     14.24
            2" x 6", Std & Btr
              2" x 6" studs, 24" centers, per MBF            --@.000 MBF    674.68         --    674.68
              12" centers (1.10 BF per SF)                  B1@.044   SF      0.75       1.60       2.35
              16" centers (.83 BF per SF)                   B1@.033   SF      0.56       1.20       1.76
              20" centers (.67 BF per SF)                   B1@.027   SF      0.45       0.98       1.44
              24" centers (.55 BF per SF)                   B1@.022   SF      0.37       0.80       1.18
              Add for each corner or partition              B1@.083   Ea     16.06       3.03     19.08
            4" x 4", Std & Btr
              Installed in wall framing, with 10% waste     B1@.064   LF      1.35       2.33       3.69

            Stud wall repair. Costs per stud added or repaired. Costs will be higher when plumbing or electrical
            lines run through the stud wall affected.
            Straighten stud by cutting saw kerf. Drive shim or screw into the kerf
              Reinforce with a plywood scab                BC@.300    Ea         --    12.08      12.08
              Remove and replace a badly warped stud       BC@.300    Ea         --    12.08      12.08

            Add stud to an existing stud wall. Remove blocking, insert an additional stud in an existing wall,
            replace blocking.
              2" x 3" x 8' stud                             B1@.300   Ea      2.33     10.94      13.27
              2" x 4" x 8' stud                             B1@.346   Ea      3.15     12.61      15.76
              2" x 6" x 8' stud                             B1@.392   Ea      5.59     14.29      19.88

            Plates. (Wall plates), Std & Btr, untreated. For pressure-treated plates see also Sill Plates in this
            chapter. Figures in parentheses indicate board feet per LF. Costs shown include 10% for waste and
            nails.
              2" x 3" Wall plates, per MBF                   --@.000 MBF    729.22         --    729.22
              2" x 3" (.55 BF per LF)                       B1@.010   LF      0.44       0.37       0.81
              2" x 4" Wall plates, per MBF                   --@.000 MBF    658.52         --    658.52
              2" x 4" (.73 BF per LF)                       B1@.012   LF      0.53       0.44       0.96
              2" x 6" Wall plates, per MBF                   --@.000 MBF    674.68         --    674.68
              2" x 6" (1.10 BF per LF)                      B1@.018   LF      0.82       0.66       1.47

            Wall Bracing. See also sheathing for plywood bracing and shear panels.
            Let-in wall bracing, using Std & Btr lumber
              1" x 4"                                       B1@.021   LF      0.69       0.77       1.45
              1" x 6"                                       B1@.027   LF      1.00       0.98       1.98
              2" x 4"                                       B1@.035   LF      0.43       1.28       1.71
            Steel strap bracing, 1-1/4" wide
              9'6" or 11'6" lengths                         B1@.010   LF      0.59       0.37       0.95
            Steel V-bracing, 3/4" x 3/4"
              9'6" or 11'6" lengths                         B1@.010   LF      0.90       0.37       1.26
            Temporary wood frame wall bracing, assumes salvage at 50% and 3 uses
              1" x 4" Std & Btr                             B1@.006   LF      0.17       0.22       0.39
              1" x 6" Std & Btr                             B1@.010   LF      0.25       0.37       0.62
              2" x 4" utility                               B1@.012   LF      0.11       0.44       0.55
              2" x 6" utility                               B1@.018   LF      0.17       0.66       0.83