Page 91 - 2018 National Home Improvement
P. 91

2018 National Home Improvement Estimator, All Rights Reserved                                    Page 72



            Breakthrough wall opening. Includes breaking an opening in an existing interior or exterior wall,
            cutting out the existing wall frame and cover, installing a header where studs or brick are removed, and
            trimming and casing the opening. Add the cost of floor and wall finish to match the existing surfaces on
            both sides of the new opening. In multi-story construction or in wide openings, a steel lintel may be
            required to support the framing above the opening. Add the cost of engineering, the lintel, and one hour
            of carpenter time for each foot of lintel length. Wall breakthrough for door or cased openingDoor or cased
            opening to 3' wide x 7' high. Includes the door frame. Add the cost of the door and jamb, as required.
              Frame wall                                    B1@5.25   Ea         --   191.40     191.40
              Add for each foot of width over 3'            B1@.700   LF         --    25.52      25.52
              Brick veneer over frame wall                  B1@6.25   Ea         --   227.80     227.80
              Add for each foot of width over 3'            B1@.750   LF         --    27.34      27.34
              Block or brick wall                           B1@6.75   Ea         --   246.00     246.00
              Add for each foot of width over 3'            B1@.850   LF         --    30.98      30.98
            Wall breakthrough for window or wall air conditioner, to 3' wide x 4' high. Includes the window frame and
            cripple stud fill below the new opening. Add the cost of the window, as required.
              Frame wall                                    B1@6.50   Ea         --   236.90     236.90
              Brick veneer over frame wall                  B1@10.5   Ea         --   382.70     382.70
              Block or brick                                B1@11.8   Ea         --   430.10     430.10


            Furring. Per SF of surface area to be covered, including typical wedging. Figures in parentheses show
            coverage, including 7% waste, typical job.
            Over masonry, utility grade
              1" furring, per MBF                            --@.000 MBF 1,626.10          --   1,626.10
              12" OC, 1" x 2" (.24 BF per SF)               B1@.025   SF      0.39       0.91       1.30
              16" OC, 1" x 2" (.20 BF per SF)               B1@.020   SF      0.32       0.73       1.05
              20" OC, 1" x 2" (.17 BF per SF)               B1@.018   SF      0.27       0.66       0.93
              24" OC, 1" x 2" (.15 BF per SF)               B1@.016   SF      0.24       0.58       0.83
              12" OC, 1" x 3" (.36 BF per SF)               B1@.025   SF      0.59       0.91       1.50
              16" OC, 1" x 3" (.29 BF per SF)               B1@.020   SF      0.47       0.73       1.20
              20" OC, 1" x 3" (.25 BF per SF)               B1@.018   SF      0.40       0.66       1.06
              24" OC, 1" x 3" (.22 BF per SF)               B1@.016   SF      0.36       0.58       0.95
            Over wood frame, utility grade
              1" furring, per MBF                            --@.000 MBF 1,626.10          --   1,626.10
              12" OC, 1" x 2" (.24 BF per SF)               B1@.016   SF      0.39       0.58       0.98
              16" OC, 1" x 2" (.20 BF per SF)               B1@.013   SF      0.32       0.47       0.80
              20" OC, 1" x 2" (.17 BF per SF)               B1@.011   SF      0.27       0.40       0.67
              24" OC, 1" x 2" (.15 BF per SF)               B1@.010   SF      0.24       0.37       0.61
              12" OC, 1" x 3" (.36 BF per SF)               B1@.016   SF      0.59       0.58       1.17
              16" OC, 1" x 3" (.29 BF per SF)               B1@.013   SF      0.47       0.47       0.95
              20" OC, 1" x 3" (.25 BF per SF)               B1@.011   SF      0.40       0.40       0.81
              24" OC, 1" x 3" (.22 BF per SF)               B1@.010   SF      0.36       0.37       0.73
            Over wood subfloor
              1" furring, per MBF                            --@.000 MBF 1,626.10          --   1,626.10
              12" OC, 1" x 2" utility (.24 BF per SF)       B1@.033   SF      0.39       1.20       1.60
              16" OC, 1" x 2" utility (.20 BF per SF)       B1@.028   SF      0.32       1.02       1.34
              20" OC, 1" x 2" utility (.17 BF per SF)       B1@.024   SF      0.27       0.88       1.15
              24" OC, 1" x 2" utility (.15 BF per SF)       B1@.021   SF      0.24       0.77       1.01
              2" furring, per MBF                            --@.000 MBF    658.52         --    658.52
              12" OC, 2" x 2" Std & Btr (.48 BF per SF)     B1@.033   SF      0.31       1.20       1.52
              16" OC, 2" x 2" Std & Btr (.39 BF per SF)     B1@.028   SF      0.25       1.02       1.27
              20" OC, 2" x 2" Std & Btr (.34 BF per SF)     B1@.024   SF      0.22       0.88       1.10
              24" OC, 2" x 2" Std & Btr (.30 BF per SF)     B1@.021   SF      0.20       0.77       0.97
   86   87   88   89   90   91   92   93   94   95   96