Redundant Scans

                             *  0 Redundant Scans – Requires 1 good decode
          ³  3  0  1  1  0  0    for a good scan.
                                 1 Redundant Scan – Requires 2 consecutive
          ³  3  0  1  1  1  0    decodes of the same bar code data for a good
                               scan.

                               2 Redundant Scans – Requires 3 consecutive
          ³  3  0  1  1  2  0    decodes of the same bar code data for a good
                               scan.

                               3 Redundant Scans – Requires 4 consecutive
          ³  3  0  1  1  3  0    decodes of the same bar code data for a good
                               scan.
                               4 Redundant Scans – Requires 5 consecutive

          ³  3  0  1  1  4  0    decodes of the same bar code for a good scan.


                               5 Redundant Scans – Requires 6 consecutive
          ³  3  0  1  1  5  0    decodes of the same bar code for a good scan.


                               6 Redundant Scans – Requires 7 consecutive
          ³  3  0  1  1  6  0    decodes of the same bar code for a good scan.


                               7 Redundant Scans – Requires 8 consecutive
          ³  3  0  1  1  7  0    decodes of the same bar code for a good scan.

        Miscellaneous Decode Features

                             *  Optional Same Symbol Check – Requires 1
          ³  1  1  8  1  1  3    different character between successive bar
                               codes to consider the bar code new.
                                 Normal Same Symbol Check – Requires 3
          ³  1  1  8  1  0  3    different characters between successive bar
                               codes to consider the bar code new.