Page 181 - Chem Service 2016 Catalogue
P. 181

CALIBRATION MIXTURE
         EPA METHOD 8015C
         Acetonitrile                Ethyl methacrylate        Acrylamide                 Isobutyl alcohol
                                                                                          Methyl methacrylate
                                                               Diethyl ether
                                     Methacrylonitrile
         2-Butanone
     EPA 8000  100ug/mL in Methanol:Water(90:10)       (12 components)
                                                               Ethyl alcohol
                                     4-Methyl-2-pentanone
         1,4-Dioxane
                                                                                          Propionitrile
                                          1mL Ampule
         M-CS8015C4AP1-1ML
         CALIBRATION MIXTURE
         EPA METHOD 8015C
         N-Nitrosodi-n-butylamine   2-Picoline
         Pyridine              o-Toluidine
         2000ug/mL in Methanol:Water (90:10)   (4 components)
         M-CS8015C5AP-1ML                 1mL Ampule
            METHOD 8020B - AROMATIC VOLATILE COMPOUNDS
          Method 8020 is applicable for the determination of the concentration of aromatic volatile organics by GC with detection by a photo-ionization
          detector (PID).
         BTEX MIXTURES                                         SURROGATE STANDARDS
         EPA METHOD 8020B, 502/524, CLP                        EPA METHOD 8020B
         Benzene                                 Ethylbenzene                          1-Bromo-4-chlorobenzene
         Toluene                                           o-Xylene     S-10022M1-1ML   100ug/ml in Methanol
         m-Xylene                                         p-Xylene  S-10022M1-5ML   100ug/ml in Methanol
         200ug/mL in Methanol         (6 components)                               4- Bromofluorobenzene
         M-BTEX1M2-1ML                1mL Ampule               S-10809M5-1ML       2000ug/mL in Methanol
         2000ug/mL in Methanol        (6 components)           S-10809M8-1ML       10000ug/mL in Methanol
         M-BTEX2M5-1ML                1mL Ampule
                                                               N-10119-100MG       1,4-Difluorobenzene
         INTERNAL STANDARDS                                    S-10119M5-1ML       2000ug/mL in Methanol
                                                               S-10119M5-5ML
                                                                                   2000ug/mL in Methanol
         EPA METHOD 8020B,
         N-10989-1G              a,a,a-Trifluorotoluene        N-11997-1G           Fluorobenzene
         S-10989M1-1ML       100ug/mL in Methanol               S-11997M5-1ML      2000ug/mL in Methanol
         S-10989M1-1ML       100ug/mL in Methanol              S-11997M5-5ML       2000ug/mL in Methanol
         S-10989M5-1ML       2000ug/mL in Methanol
         S-10989M5-1ML       2000ug/mL in Methanol
         AROMATIC VOLATILE ORGANICS MIXTURE
         EPA METHOD 8020B
         Benzene                      1,4-Dichlorobenzene              m-Xylene                 Chlorobenzene
         Ethylbenzene                 p-Xylene                         1,2-Dichlorobenzene          Toluene
         1,3-Dichlorobenzene          o-Xylene
         100ug/mL in Methanol         (10 components)
         M-AVO1M1-1ML                 1mL Ampule








            PLEASE  NOTE:

            Most Chem Service materials are overfilled approximately 10%, at the time of filling, to compensate
            for any irretrievable product remaining in the bottle. A small spatula, or micro pipette can be used to
            remove a known or weighed amount of sample to be placed into a measured amount of solvent.













    180
   176   177   178   179   180   181   182   183   184   185   186