DEGRADATION CALIBRATION MIXTURE DEGRADATION PRODUCTS MIXTURE
EPA METHOD 1618, 608, 508/508.1, 525.2,617, EPA METHOD 1618, 608, 508/508.1, 525.2,617,
625, 1656, 8080A/8081, 8250A/8270B, CLP 625, 1656, 8080A/8081, 8250A/8270B, CLP
200ug/mL 4,4’-DDT 200ug/mL 4,4’-DDD
100ug/mL Endrin 200ug/mL 4,4’-DDE
100ug/mL Endrin aldehyde
Varied concenration in tert-Butylmethyl ether (2 components) 100ug/mL Endrin ketone
M-DC508T99-1ML 1mL Ampule EPA 1600
Varied concenration in tert-Butylmethyl ether (4 components)
GPC CALIBRATION MIXTURE M-DP5081T99-1ML 1mL Ampule
EPA METHOD 1618, 1656, 1657
15,000ug/mL Bis(2-ethylhexyl)phthalate
300,000ug/mL Corn oil
1,400ug/mL Pentachlorophenol
100ug/mL Perylene
500ug/mL Sulfur-sublimed
Varied concenration in Isooctane (5 components)
M-GPC16571K99-1ML 1mL Ampule
METHOD 1656 - ORGANOHALIDE PESTICIDES
Method 1656 is applicable to determination of the organo-halide pesticides and polychlorinated biphenyls (PCBs) and other compounds
amenable to extraction and analysis by wide-bore capillary column gas chromatography (GC) with halogen-specific detectors (HSD).
DEGRADATION CALIBRATION MIXTURE DEGRADATION PRODUCTS MIXTURE
EPA METHOD 1656, 608, 508/508.1, 525.2,617, EPA METHOD 1656, 608, 508/508.1, 525.2,617,
625, 1618, 8080A/8081, 8250A/8270B, CLP 625, 1656, 8080A/8081, 8250A/8270B, CLP
200ug/mL 4,4’-DDT 200ug/mL 4,4’-DDD
100ug/mL Endrin 200ug/mL 4,4’-DDE
100ug/mL Endrin aldehyde
Varied concenration in tert-Butylmethyl ether (2 components) 100ug/mL Endrin ketone
M-DC508T99-1ML 1mL Ampule
GPC CALIBRATION MIXTURE Varied concenration in tert-Butylmethyl ether (4 components)
1mL Ampule
M-DP5081T99-1ML
EPA METHOD 1656, 1618, 1657 DIBUTYL CHLORENDATE STANDARDS
15,000ug/mL Bis(2-ethylhexyl)phthalate
300,000ug/mL Corn oil EPA METHOD 1656
1,400ug/mL Pentachlorophenol Dibutyl chlorendate
100ug/mL Perylene S-11638B5-1ML 2000ug/ml in Acetone
500ug/mL Sulfur-sublimed S-11638B5-5ML 2000ug/ml in Acetone
Varied concenration in Isooctane (5 components) S-11638X4-1ML 1000ug/ml in Methylene Chloride
S-11638X4-5ML 1000ug/ml in Methylene chloride
M-GPC16571K99-1ML 1mL Ampule
METHOD 1657 - ORGANOPHOSPHOROUS PESTICIDES
Method 1657 is applicable to the determination in waters, soils, sediments, and sludges, organophosphorus pesticides and additional compounds
amenable to extraction and analysis by wide-bore capillary column gas chromatography (GC) with a flame photometric detector (FPD).
SURROGATE SPIKING MIXTURE SURROGATE STANDARDS
EPA METHOD 1657 EPA METHOD 1657
Tributyl phosphate N-13645-1G Tributyl phosphate
Triphenyl phosphate S-13645B5-1ML 2000ug/ml in Acetone
S-13645B5-5ML 2000ug/ml in Acetone
2000ug/mL in Acetone (2 components)
M-SS1657B5-1ML 1mL Ampule N-13708-1G Triphenyl phosphate
S-13708T3-1ML 500ug/ml in tert-Butylmethyl ether
SURROGATE STANDARDS S-13708T3-5ML 500ug/ml in tert-Butylmethyl ether
EPA METHOD 1657 ADDITIONAL ANALYTE
S,S,S-Tributyl phosphorotrithioate EPA METHOD 1657
S-13194T1-1ML 100ug/mL in tert-Butylmethylether Carbophenothion methyl
S-13194T1-5ML 100ug/mL in tert-Butylmethylether MET-11408AM1-1ML 1000ug/ml in Methanol