Page 188 - Chem Service 2016 Catalogue
P. 188

METHOD 8082/8082A - POLYCHLORINATED BIPHENYLS
          Method 8082 is applicable for the determination of polychlorinated biphenyls (PCBs) by capillary column gas chromatography

         AROCHLOR CALIBRATION STANDARDS                       INTERNAL & SURROGATE STANDARDS
         MIXTURE                                              EPA METHOD 8082/8082A
         EPA METHOD 8082/8082A                                BZ-209-10MG      Decachlorobiphenyl
         Arochlor 1016                                        BZ-209J1-1ML     100ug/ml in Hexane                    EPA 8000
                                                              BZ-209J1-5ML
                                                                               100ug/ml in Hexane
         Arochlor 1260
                                                              BZ-209B3-1ML     500ug/ml in Acetone
         1000ug/mL in Hexane -      (2 components)            BZ-209B3-5ML     500ug/ml in Acetone
         M-CSM8082J4-1ML     1mL Ampule                       BZ-209U4-1ML     1000ug/ml in Toluene
         M-CSM8082J4-5ML     5mL Ampule                       BZ-209U4-5ML     1000ug/ml in Toluene
                                                              BZ-209J4-1ML     1000ug/ml in Hexane
                                                              BZ-209J4-5ML     1000ug/ml in Hexane
                                                              N-10542-100MG  2,4,5,6-Tetrachloro-m-xylene
                                                              S-10542B3-1ML  500ug/ml in Acetone
                                                              S-10542B3-5ML  500ug/ml in Acetone
                                                              S-10542M2-1ML  200ug/ml in Methanol
                                                              S-10542M2-5ML  200ug/ml in Methanol
            METHOD 8090 - NITROAROMATICS & CYCLIC KETONES

          Method 8090 is applicable for the determination of nitroaromatics and cyclic ketones
         BASE NEUTRALS SURROGATE STANDARDS                    SURROGATE STANDARDS
         MIXTURES                                             EPA METHOD 8090
         EPA METHOD 8090, 8110, 8120A,                        N-10359-1G       2-Fluorobiphenyl
                                                              S-10359X5-1ML  2000ug/ml in Methylene chloride
         8250A/8270B, CLP                                     S-10359X5-5ML  2000ug/ml in Methylene chloride
         2-Fluorobiphenyl                                     S-10359M1-1ML  100ug/ml in Methanol
         p-Terphenyl-d                                        S-10359M1-5ML  100ug/ml in Methanol
         Nitrbenzene-d5
                                                              N-112661-1G      Nitrobenzene-d
                                                                                          5
         1000ug/mL in Methylene chloride -      (3 components)  S-12661M5-5ML  2000ug/ml in Methanol
         M-CLP2X4-1ML                          1mL Ampule
         M-CLP2X4-5ML                          5mL Ampule     N-12795-50MG     p-Terphenyl-d
                                                              S-12795X5-1ML  2000ug/ml in Methylene chloride
         5000ug/mL in Methylene chloride -      (3 components)  S-12795X5-5ML  2000ug/ml in Methylene chloride
         M-CLPH2X7-1ML                         1mL Ampule
         M-CLPH2X7-5ML                         5mL Ampule
            METHOD 8091 - NITROAROMATICS & CYCLIC KETONES

          Method 8091 is applicable for the determination of nitroaromatics and cyclic ketones utilizing a capillary column technique

         INTERNAL STANDARDS                                   SURROGATE STANDARDS
         EPA METHOD 8091                                      EPA METHOD 8091
         N-12159-100MG  Hexachlorobenzene                     N-10036-500MG  1-Chloro-3-nitrobenzene
         S-12159K4-1ML  1000ug/ml in Isooctane                S-10036K4-1ML  1000ug/mL in Isooctane
         S-12159K4-5ML  1000ug/ml in Isooctane                S-10036K4-5ML  1000ug/mL in Isooctane
         S-12159M1-1ML  100ug/ml in Methanol
         S-12159M1-5ML  100ug/ml in Methanol
         RCRA ANALYTE MIXTURE
         EPA METHOD 8091
         1,4-Dintrobenzene                2,6-Dinitrotoluene       Nitrobenzene
         2,4-Dinitrotoluene               1,4-Napthquinone         Pentachloronitrobenzene
         100ug/mL in Isooctane            (6 components)
         M-CS8091A1K1-1ML                 1mL Ampule

















                                                                                                                    187
   183   184   185   186   187   188   189   190   191   192   193