METHOD 8310 - POLYNUCLEAR AROMATIC HYDROCARBONS
Method 8310 is applicable for determination of polynuclear aromatic hydrocarbons (PAHs) in ground water and wastes. Method 8310 provides
high performance liquid chromatographic (HPLC) conditions for the detection of PPB levels of certain polynuclear aromatic hydrocarbons. If
the interferences prevent proper detection of the analytes, this method may also be performed on extracts that have undergone cleanup using
silica gel column cleanup (Method 3630).
POLYNUCLEAR AROMATIC HYRDOCARBONS (PAH) EPA 8000
EPA METHOD 8310, 550.1, 610, 8100, 8270B, CLP
Acenaphthene Acenaphthylene Anthracene 1,2-Benzanthracene
Benzo(b)fluoranthene Benzo(k)fluoranthene 1,12-Benzoperylene Benzo(a)pyrene
Chrysene 1,2:5,6-Dibenzanthracene Fluoranthene Fluorene
Indeno(1,2,3-C,D)pyrene Naphthalene Phenanthrene Pyrene
100ug/mL in Methanol (16) components)
M-PPH10M1-1ML 1mL Ampule
M-PPH10M1-5ML 5mL Ampule
200ug/mL in Acetonitrile (16) components)
M-PNA550A2-1ML 1mL Ampule
2000 ug/ml in CH2Cl2:Benzene (50:50) (16) components)
M-PPHC6AD5-1ML 1mL Ampule
M-PPHC6AD5-5ML 5mL Ampule
PAH CONTROL SAMPLE MIXTURE
EPA METHOD 8310 , 550.1, 610, 8100,
100ug/mL Acenaphthene 100ug/mL Acenaphthylene
100ug/mL Anthracene 10ug/mL 1,2-Benzanthracene
10ug/mL 1,12-Benzoperylene 10ug/mL Benzo(a)pyrene
10ug/mL Benzo(b)fluoranthene 5ug/mL Benzo(k)fluoranthene
10ug/mL Chrysene 10ug/mL 1,2:5,6-Dibenzanthracene
10ug/mL Fluoranthene 100ug/mL Fluorene
10ug/mL Indeno(1,2,3-C,D)pyrene 100ug/mL Naphthalene
100ug/mL Phenanthrene 10ug/mL Pyrene
Varied concentration in Acetonitrile- ( 16) components)
M-CSM8310A99-1ML 1mL Ampule
SURROGATE STANDARDS
EPA METHOD 8310
N-11570-1G Decafluorobipneyl
S-11570A5-1ML 2000ug/mL in Acetonitrile
S-11570A5-5ML 2000ug/mL in Acetonitrile
S-11570B4-1ML 1000ug/mL in Acetone
S-11570B4-5ML 1000ug/mL in Acetone
S-11570X5-1ML 2000ug/mL in Methylene chloride
S-11570X5-5ML 2000ug/mL in Methylene chloride
METHOD 8315 - CARBONYL COMPOUNDS
Methods 8315/8315A are applicable for determination of carbonyl compounds by high performance liquid chromatography (HPLC.
DERIVATIZED CARBONYL MIXTURE (OPTION #1)
EPA METHOD 8315/8315A
Acetaldehyde (DNPH Derivative) n-Butyraldehyde (DNPH Derivative) Crotonaldehyde (DNPH Derivative)
Cyclohexanone (DNPH Derivative) Decyl aldehyde (DNPH Derivative) Formaldehyde (DNPH Derivative)
Heptaldehyde (DNPH Derivative) Hexaldehyde (DNPH Derivative) Nonanal (DNPH Derivative)
Octyl aldehyde (DNPH Derivative) Propionaldehyde (DNPH Derivative) Valeraldehyde (DNPH Derivative)
100ug/mL in Acetonitrile (12 components)
M-DCC83151A1-1ML 1mL Ampule
DERIVATIZED CARBONYL MIXTURE (OPTION #2)
EPA METHOD 8315/8315A
Acetaldehyde (DNPH Derivative) Acetone (DNPH Derivative) Acrolein (DNPH Derivative)
Benzaldehyde (DNPH Derivative) n-Butyraldehyde (DNPH Derivative) Crotonaldehyde (DNPH Derivative)
2,5-Dimethylbenzaldehyde (DNPH Derivative) Formaldehyde (DNPH Derivative) Hexaldehyde (DNPH Derivative)
Isovaleraldehyde (DNPH Derivative) Propionaldehyde (DNPH Derivative) o-Tolualdehyde (DNPH Derivative)
m-Tolualdehyde (DNPH Derivative) p-Tolualdehyde (DNPH Derivative) Valeraldehyde (DNPH Derivative)
100ug/mL in Acetonitrile (15 components)
M-DCC83152A1-1ML 1mL Ampule