DI - 306             Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts


                             Failure phenomenon                            Phenomenon description

                                                              Although the ignition switch is placed at "ON" position, the
              The whole combination instrument is not working
                                                              entire combination instrument fails to work.
              Diagnosis procedure
              1. Check the combination instrument fuse

              a. Ignition switch: LOCK.
              b. Open the body harness fuse box cover.

              c. Remove combination instrument fuse F12(5A) and F29(10A).
                                                           Caution
              Dismount  the  fuse  with  a  special  fuse  remover.  Do  not  pull  it  out  directly  with  hands,  which  may
              damage the fuse



                                                        d. Check whether the combination instrument fuse F12 (6A)
                    Disconnect           Normal         and fuse F29(10A) are burnt out.











              Check if the fuse is broken
              Yes>replace with the same spec fuse

              NO>go to Step 2.
              2. Check the power circuit of combination instrument.

              a. Ignition switch: LOCK.
              b. Respectively disconnect the combination instrument connector B014.
              c. Ignition switch: ON.

                                                        d. Measure the voltage between the B014 terminal 2 and the
                                                        ground with the multimeter in voltage gear.
                                                        Standard voltage:

                                                         Multimeter connecting terminal   Standard value

                                                               B004(2)-grounding       Storage battery voltage