Page 365 - Foton Workshop Manual - Auman EST-M
P. 365

Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts   DI - 311

              Diagnosis procedure                                                                                 IN
              1. Check the backlight circuit of combination instrument.

              a. Ignition switch: LOCK.                                                                           DI
              b. Disconnect the connector B015 of combination instrument.
              c. Ignition switch: ON.                                                                             EG

                                                        d. Measure the voltage between the combination instrument
                                                        connector  B015  terminal  21  and  the  ground  with  the   TR
                                                        multimeter in voltage gear.
                                                        Standard voltage:                                         AX

                                                          Multimeter connecting terminal   Standard value
                                                                                                                  FR
                                                              B0015(21)-grounding      Storage battery voltage



                                                                                                                  ST
              Check if the result is ok?

              Yes>go to Step 2.                                                                                   BR
              NO>repair or replace the harness.
              2. Check the combination switch                                                                     BW

              Caution
              If the combination instrument is broken, normally non-professional personnel cannot check and repair   EL
              precisely. At present often using the substitution judgment method for service.

              a. Replace with a new or normal combination instrument.

              b. Connect the circuit, restart the ignition switch and check if the failure is fixed.
                                                           Caution

              The combination instrument for replacement must be the same specification as previously used.
              Is the test result ok?
              Yes>repair or replace the combination instrument.

                                                           Caution
              Internal  combination  instrument  service  needs  professional  personnel.  Others  shall  not  dismount
              anything.

              NO>retest the above steps.













                                                          DI-311
   360   361   362   363   364   365   366   367   368   369   370