DI - 340             Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts


                                                        c. Open the door, use a multimeter to measure the resistance
                                                        between  1#  terminal  of  door  unlocked  switch  connector
                                                        G004 and earthing.
                                                        Standard resistance:

                                                           Multimeter connecting terminal   Standard value

                                                                G004(1)- grounding           About 0Ω


              Check if the result is ok?
              Yes> retest the above steps.

              No > repair or replace the door unlocked switch.
































































                                                          DI-340