Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts DI - 403
4. Check the earth circuit of diagnosis interface IN
a. Use a multimeter to respectively measure the resistance
between 4# and 5# terminals of diagnosis interface B018 DI
and the earthing.
Standard resistance: EG
Multimeter connecting terminal Standard value
TR
B0018(4)-grounding About 0Ω
B0018(5)-grounding About 0Ω
AX
Check if the result is ok?
Yes>go to Step 5.
FR
No > check whether the earthing point is firm or replace the defective connector or wire harness.
5. Measure CAN bus communication circuit ST
a. Measure the resistance between 6# and 14# terminals of
diagnosis interface B18. BR
Standard resistance:
Multimeter connecting terminal Standard value BW
B018(6)-B018(14) About 60Ω
EL
Check if the result is ok?
Yes>go to Step 6.
No > check whether the terminal resistor which is connected with each CAN bus end is damaged
and whether CAN bus has open circuit.
6. Check the control module
a. Connect a diagnostic apparatus, check whether the communication is established with other control
modules.
Check if the result is ok?
Yes > control module fault, replace the control module.
No>check the reason from other failures.