DI - 404             Diagnosis - Diagnosis-fault diagnosis of electronic and electrical parts

              Basic inspection
              1. Check the diagnosis interface

                                                        a. The diagnosis interface is located below dashboard.
                                                        b. The diagnosis interface is 16# terminal.













              Terminal number           Function              Terminal number            Function

                     4        Power supply ground                   9         Instrument K line

                     5        Signal ground                         14        CAN-L

                     6        CAN-H                                 16        Battery power supply

                     7        K line
                                                           Caution
              The terminals not indicated in the table are empty terminals.

              2. Measure CAN bus voltage

                                                        a.  Measure  the  voltage  between  the  6#  terminal  (CAN_H
                                                        conductor)  and  14#  terminal  (CAN_L  conductor)  of
                                                        diagnosis  interface  B018  and  the  body  earthing,  and
                                                        determine whether there is short circuit in CAN bus power
                                                        supply (such as the conductor with higher voltage than CAN
                                                        communication  circuit)  and  earthing  (such  as  the
                                                        conductor  with  lower  voltage  than  CAN  communication
                                                        circuit).

                                                        Standard voltage:

                                                          Multimeter connecting terminal   Standard value

                                                               B0018(6)-grounding           2.5~3.5V

                                                              B0018(14)-grounding           1.5~2.5V