Engine section – Engine (Cummins ISF3.8)                  EG - 245

              Generator                                                                                           IN
              Check and repair

                                                        1. Remove the generator                                   DI

                                                        a. Switch off the ignition switch
                                                                                                                  EG
                                                        b. Disconnect the cable of battery negative pole

                                                        c. Remove generator excitation wire fixing nut.
                                                                                                                  TR
                                                        d.  Remove  the  generator  binding  post  fixing  nut  at  the
                                                        output end.
                                                                                                                  AX



                                                        e. Turn the tension pulley and remove the drive belt.     FR


                                                                                                                  ST


                                                                                                                  BR

                                                                                                                  BW


                                                        f.  Remove  the  generator  fixing  bolts  and  remove  the   EL
                                                        generator assembly.








              2. Check the generator

              a. Check if the generator is cracked, worn and rotating smoothly without jam.
              b. Check if there is short circuit and open circuit inside the generator, if the terminal is corroded and burnt.
              c. Connect the red test lead of the multimeter to the "armature" of the generator and the black test lead to the
              housing so that the engine runs at medium speed or above. The standard voltage of the 12V electrical system
              shall  be  about  14V.  If  the  measured  voltage  is  the  battery  voltage,  it  indicates  that  the  generator  is  not

              generating electricity.