Page 2165 - Foton Workshop Manual - Aumark (BJ1099)
P. 2165
DIAGNOSIS-POWER REARVIEW MIRRORS 62-113
2. Check the electric rearview mirror motor
(a). Ignition switch:"LOCK".
(b). Disconnect left electric rearview mirror assembly connectors J03.
(c). Disconnect the continuity of the No.4 & 62
No.5 terminal of left electric rearview mirror
OFF T.S
assembly connectors J03.
J30
4 3 2 1
Connect the pin by
8 7 6 5 Continuity
multimeter
4 6
Ω J03 (4) - J03 (6) Exist
fuwx62404
Is the result normal?
Yes>To step3.
No >replace electric rearview mirror motor.
3. Check harness and connector (Electric rearview mirror switch-left rearview)
(a). Ignition switch:"LOCK".
(b). Disconnect left electric rearview mirror assembly connectors J03.
(c). Disconnect the electric rearview mirror switch connector J08.
(d). Measure the resistance according to values
in the table below.
OFF T.S
J08 J 30 Standard resistance: (check whether there
is an open circuit)
4 3 2 1
8 7 6 5 3 2 1 8 7 6 5
Connect the pin by
6 3 6 4 Standard value
multimeter
Ω
J08 (6) - J03 (6)
fuwx62405
< 2 Ω
J08 (3) - J03 (4)
Is the result normal?
Yes>Replace the electric left rearview mirror assembly.
No >Repair or replace the harness.
Page 2165