Page 2242 - Foton Workshop Manual - Aumark (BJ1099)
P. 2242
62-190 DIAGNOSIS-REAR WINDOW DEFROSTING SYSTEM
(c). Measure the voltage with the multimeter on
the voltage range.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
M09 (1) -Grounding Battery volt
Is the result normal?
Yes>To step 6.
No >Repair or replace the harness.
6. Check the harness and connector (defroster switch-grounding)
(a). Ignition switch:"ON".
(b). Disconnect air conditioning controller
connector C42.
fuwx62 606
(c). Measure the voltage with the multimeter on
the voltage range.
Standard Voltage:
Connect the pin by Standard Voltage
multimeter
C42 (A10) -Grounding Battery volt
Is the result normal?
Yes>To step 7.
No >Replace the starter cutoff relay R04.
Page 2242