Page 2329 - Foton Workshop Manual - Aumark (BJ1099)
P. 2329
DIAGNOSIS-HORN SYSTEM 62-277
Is the result normal?
Yes>To step 5.
No >Replace the horn switch.
5. Check the harness and the connector (BCM control unit-clock spring)
62
(a). Ignition switch:"LOCK".
(b). Disconnect the BCM control unit connector
C57.
fuwx62302
(c). Disconnect the connector C17 of the clock
spring.
fuwx62 771
(d). Measure the resistance with the multimeter
C17 on the resistance range.
OFF T.S
Standard resistance: (check whether there
6 5 4 3 2 1
C57 12 11 10 9 8 7
is an open circuit)
Ω
Connect the pin by
7 6 5 4 3 2 1 multimeter Standard value
23 22 21 20 19 18 17
C57(5)- C17(1) < 2 Ω
fuwx67542
Page 2329