Page 2357 - Foton Workshop Manual - Aumark (BJ1099)
P. 2357
DIAGNOSIS-LIGHTING SYSTEM 62-305
(c). Measure the voltage between the No.2
terminal of the left front combination lamp
connector A28 and the grounding with a
multimeter.
Standard resistance: (check whether there
is a short circuit) 62
Connect the pin by Standard value
multimeter
A28(2) - Grounding > 1 MΩ
Is the inspection result normal?
Yes>Find the causes from other symptoms.
No >Maintain the short circuit to ground of the harness between the connector.
Page 2357