Page 2516 - Foton Workshop Manual - Sauvana
P. 2516
62-464 DIAGNOSIS-AUTOMATIC TRANSMISSION
(c). Examine reversing lamp relay R02 with a
multimeter.
OFF
Standard resistance:
R02
2
Multimeter
4 5 3 Specified
Ω Conditions connection
1 pin value
Normalcy 1 - 2 Breakover
fuwx62354
Normalcy 3 - 5 ≥ 1MΩ
To impose
voltage between 3 - 5 < 2Ω
pin 1 and 2
Check if the result is normal?
YES> To step 4.
NO> Replace reversing lamp relay .
4. Detect open circuit of wiring harness
(a). Ignition switch: "LOCK".
(b). Disconnect reversing lamp relay R02.
(c). Disconnect TCU connector P01 .
(d). Examine resistance value between
reversing lamp relay R02 and TCU P01;
OFF
Standard resistance:(Check for open
circuit)
1
3 P01 R02
4 2
5 2 Multimeter
10 8 6 7 Standard value
11 9 4 5 3
12 connection pin
15 13 14 1
16
R02(1) - P01(15) ≤ 2 Ω
15 7 1 2
R02(2) - P01(7) ≤ 2 Ω
Ω
fuwx62953
Check if the result is normal?
YES>Replace the transmission
NO>Fix or change the harness.
Page 2516