Page 1028 - Foton Workshop Manual - Tunland (AT)
P. 1028

04-882                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04
                                         C036           C036(E11) - C008                  < 2 Ω
                                                               (17)





                                       C008









                                            ftwxd041401

           Check whether the result is normal?

           Yes> Replace BCM control unit.
           No > Maintenance or replace harness.



















































                                                                                                        Page 1028
   1023   1024   1025   1026   1027   1028   1029   1030   1031   1032   1033