Page 1503 - Foton Workshop Manual - Tunland (AT)
P. 1503

COOLING - COOLING SYSTEM                                 17-5

                                                           (c)    Disconnect the electronic fan connector.



















                                                                                                                     17




                                                           (d)    Test the electronic fan with battery, current
                                                                  meter and wires.

                                                                  "1" refers to the negative pole of the battery.
                                                                  "2" refers to the positive pole of the battery in
                                                                  the serial connected with a current connected
                                                                  with a t meter. "3" refers to the negative pole
                                                                  of the main electronic fan. "4" refers to the
                                                                  low-speed level of the master electronic fan.
                                                                  "5" refers to the high-speed level of the master
                                                                  electronic fan. "6" refers to the negative pole
                                                                  of the supplementary electronic fan. And "7"
                                                                  refers to the high-speed level of the
                                                                  supplementary electronic fan.
                                                                  •      Connect "1" to "3" and "2" to "4". Now
                                                                         the master electronic fan runs in low
                                                                         speed and the current meter
                                                                         shows≤10A.
                                                                  •      Connect "1" to "3" and "2" to "5". Now
                                                                         the master electronic fan runs in high
                                                                         speed and the current meter shows
                                                                         ≤17A.
                                                                  •      Connect "1" to "6" and "2" to "7". Now
                                                                         the supplementary electronic fan runs
                                                                         in high speed and the current meter

                                                                         shows≤19A.

















                                                                                                        Page 1503
   1498   1499   1500   1501   1502   1503   1504   1505   1506   1507   1508