04-30                  DIAGNOSTICS - ANTI-LOCK BRAKING SYSTEM (ABS)

           Diagnostic step

                NOTICE

           •      To implement the following steps, ensure that reverse lamp switch is grounded
                  properly.
           •      Before conducting electric diagnosis, do refer to the reference circuit diagram
      04
                  and the element information.
           •      Before conducting measurement, check the pins of connectors for rupture,
                  looseness and rust, and ensure that the pins are contacted properly.
           •      If the connection is good, check the sensor signal voltage when moving the
                  connector and harness. If a fault occurs, the voltage display on the diagnostic
                  instrument will change.


           1 .    DTC inspection
           (a)    Ignition switch: OFF.
           (b)    Connect the diagnostic apparatus.
           (c)    Use the diagnostic apparatus, read the fault code.
           (d)    Confirm whether there is a fault code related to reverse lamp switch ?

           Is the inspection result normal?
           YES>To step 2.

           NO>Intermittent trouble exists.

           1 .    Check the power supply of combination instrument

                                                      (a)    disconnect the connector A006 of the ABS
                                                             module.