Page 180 - Foton Workshop Manual - Tunland (AT)
P. 180

04-34                  DIAGNOSTICS - ANTI-LOCK BRAKING SYSTEM (ABS)


           (a)    Ignition switch: OFF.
           (b)    Connect the diagnostic apparatus.
           (c)    Use the diagnostic apparatus, read the fault code.
           (d)    Confirm whether there is a fault code related to ECU supply voltage?
           Is the inspection result normal?
      04
           YES>To step 2.
           NO>Intermittent trouble exists.


           2 .    Check fuse.
           (a)    Ignition switch: OFF.

                                                      (b)    Check fuse in the indoor fusebox:
                                                             •     F26(10A)























           Is the inspection result normal?
           YES>To step 3.
           NO>replace fuse.


           3 .    Check the battery voltage.
                  Standard voltage :11V~14V

           Check whether the result is normal?
           YES> go to step 4

           NO >replace battery or generator.

           4 .    Check ABS/ESP power supply circuit.
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Disconnect connector A006 of ABS/ESP.
           (d)    Connect the battery negative cable.
           (e)    Ignition switch: ON.










                                                                                                         Page 180