Page 248 - Foton Workshop Manual - Tunland (AT)
        P. 248
     04-102                     DIAGNOSTICS - ENGINE CONTROL SYSTEM
      04
           Remove the blown-out fuse, and measure the resistance between the load side of the
           blown-out fuse and the ground. Turn off all switches connected to the circuit where the said
           fuse stays. If the resistance measured at this moment approximates to 0, a short-circuit must
           occur in some places of the switches or loads. If the resistance is not 0, no short circuit exist
           at this moment; however, transient short circuit may cause fuse burn-out.
           Major factors leading to short circuits are listed as follows:
           •      Harness is nipped up by the vehicle body
           •      Sheath of the harness is damaged due to wear or heat
           •      Water enters into the connecters or circuits
           •      Human errors (mal-operation short circuit etc.)
            1                                               Battery
            2                                               Fuse
            3                                               Load switch
            4                                               Fuse burn-out
            5                                               Short circuit occurring position
                                                                                                         Page 248





