04-132                     DIAGNOSTICS - ENGINE CONTROL SYSTEM


             Failure code    Diagnostic items (DTC definition)                Trouble location
                                                                     • Postprocessing DPF temperature
                                                                       sensor and its harness
                                                                     • CAN bus and its harness
                                                                     • ECM
      04
                                                                     • Postprocessing DPF temperature
                             Postprocessing diesel particulate fil-    sensor module
            P4158            ter temperature sensor module - In- • Postprocessing DPF temperature
                             telligent device or component fault       sensor and its harness
                                                                     • ECM

                                                                     • Atmospheric pressure sensor
                                                                     • The signal circuit in the engine
                             Atmospheric pressure sensor circuit       harness or sensor is open or
            P222             - Voltage is below normal or shorted      shorted to ground
                             to high voltage power supply            • Power line is open or shorted to
                                                                       ground
                                                                     • ECM

                                                                     • Crankshaft position sensor
                             Engine crankshaft speed / position - • Crankshaft position sensor connec-
            P234             data is valid but above normal oper-      tor is in poor contact and the sen-
                             ating range - highest severity level      sor harness is open or shorted
                                                                     • ECM

                                                                     • Crankshaft position sensor
                             Sensor power 3 circuit - voltage is     • Crankshaft position sensor connec-
            P238             below normal or shorted to low volt-      tor is in poor contact and the sen-
                             age power supply                          sor harness is open or shorted
                                                                     • ECM

                                                                     • Crankshaft position sensor
                             Sensor power 3 circuit - voltage is     • Crankshaft position sensor connec-
            P239             above normal or shorted to low volt-      tor is in poor contact and the sen-
                             age power supply                          sor harness is open or shorted
                                                                     • ECM

                                                                     • Atmospheric pressure sensor
                                                                     • Open circuit in harness, connector
                             Atmospheric pressure sensor circuit
                                                                       or sensor circuit
            P221             - voltage is above normal or shorted
                                                                     • The signal circuit is short to the
                             to high voltage power supply
                                                                       sensor power or battery voltage
                                                                     • ECM

                                                                     • Engine coolant temperature sensor
                             Engine coolant temperature 1 sensor • Signal in wire harness is short cir-
            P145             circuit-Voltage below normal or           cuit to the ground
                             shorted to high voltage power supply • Signal in sensor is shorted to the
                                                                       loop circuit or to the ground