Page 433 - Foton Workshop Manual - Tunland (AT)
P. 433

DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-287

                 P2373,P2374,P2554-EXHAUST PRESSURE SENSOR FAILURE

                 P2373-EXHAUST PRESSURE SENSOR CIRCUIT -VOLTAGE IS
                 ABOVE NORMAL OR SHORTED TO HIGH VOLTAGE POWER

                 SUPPLY
                 P2374-EXHAUST PRESSURE SENSOR CIRCUIT -VOLTAGE IS                                                   04
                 BELOW NORMAL OR SHORTED TO LOW VOLTAGE POWER

                 SUPPLY
                 P2554-EXHAUST PRESSURE - DATA IS UNSTABLE,

                 INTERMITTENT OR INCORRECT
                 Description

                 1 .    An exhaust pressure sensor is used to measure the exhaust pressure of the
                        exhaust manifold.The engine control module (ECM) uses this information to
                        control the operation of the emissions and exhaust gas recirculation (EGR)
                        valves.The ECM provides a 5 volt power supply to the exhaust pressure sensor
                        through the sensor power circuit.The ECM also provides a ground to the sensor
                        circuit.The exhaust pressure sensor provides a signal to the ECM through the
                        exhaust pressure sensor signal circuit.The signal voltage of the sensor will vary
                        depending on the pressure of the exhaust manifold.
                 Circuit Diagram


















































                                                                                                         Page 433
   428   429   430   431   432   433   434   435   436   437   438