Page 435 - Foton Workshop Manual - Tunland (AT)
P. 435

DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-289


                      NOTICE

                 •      To implement the following steps, ensure that ECM is grounded properly.
                 •      Before conducting electric diagnosis, do refer to the reference circuit diagram
                        and the element information.
                 •      Before conducting measurement, check the pins of connectors for rupture,
                                                                                                                     04
                        looseness and rust, and ensure that the pins are contacted properly.
                 •      If the connection is good, check the sensor signal voltage when moving the
                        connector and harness. If a fault occurs, the voltage display on the diagnostic
                        instrument will change.


                 1 .    DTC inspection
                 (a)    Ignition switch: OFF.
                 (b)    Connect the diagnostic apparatus.
                 (c)    Use the diagnostic apparatus, read the fault code.
                 (d)    Confirm whether there is fault code related to exhaust pressure sensor?
                 Is the inspection result normal?

                 YES>To step 2.
                 NO>Intermittent trouble exists.


                 2 .    Check exhaust pressure sensor circuit
                 (a)    Ignition switch: OFF.
                 (b)    Disconnect the battery negative cable.
                 (c)    Disconnect the exhaust pressure sensor connector E16.
                 (d)    Connect the battery negative cable.
                 (e)    Ignition switch: ON.

                                                           (f)    Use a multimeter to measure the voltage
                                                                  between the pin 1 of the exhaust pressure
                                                                  sensor connector E16 and ground.
                                                                  Standard voltage

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                                E16(1)-ground                4.75~5.25 V











                 Is the inspection result normal?
                 YES>To step 3.

                 No > Maintain or replace the harness.