Page 452 - Foton Workshop Manual - Tunland (AT)
P. 452

04-306                     DIAGNOSTICS - ENGINE CONTROL SYSTEM

                                                      (f)    Use a multimeter to measure the resistance
                                                             between the pin 2, 3 of the DPF temperature
                                                             sensor connector Q01 and the pin 15, 16 of
                                                             ECM connector E01 respectively.

                                                             Standard resistance

      04                                               Multimeter connection
                                                                                      Standard value
                                                                 pin
                                                       Q01(2)- E01(15)                    <10 Ω

                                                       Q01(3)- E01(16)                    <10 Ω







                                                      (g)    Use a multimeter to measure the resistance
                                                             between the pin 2, 3 of DPF temperature
                                                             sensor connector Q01 and the ground.
                                                             Standard resistance

                                                       Multimeter connection
                                                                                      Standard value
                                                                 pin

                                                         Q01(2)- ground                  >10 MΩ

                                                         Q01(3)- ground                  >10 MΩ








           Is the inspection result normal?
           YES>To step 4.

           No > Maintain or replace the harness.

           4 .    Replace DPF temperature sensor
           (a)    Replace DPF temperature sensor.
           (b)    Use a diagnostic apparatus to perform DTC verification procedures.
           (c)    Implement the steps to read sensor data stream.
           (d)    Check whether DTC exists.

           Is the inspection result normal?
           YES>Replace DPF temperature sensor

           NO >To step 5.

           5 .    Replace ECM
           (a)    Replace ECM.
           (b)    Use a diagnostic apparatus to perform DTC verification procedures.
           (c)    Implement the steps to read sensor data stream.





                                                                                                         Page 452