Page 457 - Foton Workshop Manual - Tunland (AT)
P. 457

DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-311

                                                           (e)    Use a multimeter to measure the resistance
                                                                  between the pin1 of DPF temperature sensor
                                                                  connector Q01 and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin                                           04
                                                               Q01(1)- ground                   <10 Ω












                                                           (f)    Use a multimeter to measure the resistance
                                                                  between the pin 2, 3 of the DPF temperature
                                                                  sensor connector Q01 and the pin 15, 16 of
                                                                  ECM connector E01 respectively.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                             Q01(2)- E01(15)                    <10 Ω
                                                             Q01(3)- E01(16)                    <10 Ω







                                                           (g)    Use a multimeter to measure the resistance
                                                                  between the pin 2, 3 of DPF temperature
                                                                  sensor connector Q01 and the ground.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                               Q01(2)- ground                  >10 MΩ
                                                               Q01(3)- ground                  >10 MΩ









                 Is the inspection result normal?
                 YES>To step 5.
                 No > Maintain or replace the harness.