Page 478 - Foton Workshop Manual - Tunland (AT)
P. 478
04-332 DIAGNOSTICS - ENGINE CONTROL SYSTEM
(c) Disconnect DPF differential pressure sensor Q02.
(d) Connect the battery negative cable.
(e) Ignition switch: ON.
(f) Use a multimeter to measure the voltage
between the pin 3 of DPF pressure sensor
04 connector Q02 and the ground.
Standard voltage
Multimeter connection
Standard value
pin
Q02(3)- ground 4.75~5.25 V
Is the inspection result normal?
YES>To step 4.
No > Maintain or replace the harness.
4 . Check DPF pressure sensor harness
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect DPF differential pressure sensor Q02.
(d) Disconnect connector E01 of ECM.
(e) Use a multimeter to measure the voltage
between the pin1, 2 of DPF pressure sensor
connector Q02 and the pin 41, 94of ECM
connector E01.
Standard resistance
Multimeter connection
Standard value
pin
Q02(1)- E01(41) <10 Ω
Q02(2)- E01(94) <10 Ω
Page 478