04-336 DIAGNOSTICS - ENGINE CONTROL SYSTEM
(b) Check whether there is a leak inside the EGR valve.
(c) Check whether the EGR valve is locked in a closed position.
Is the inspection result normal?
YES>To step 3.
04 NO>Check the fault location.
3 . Check EGR valve circuit
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect the EGR valve connector E18.
(d) Connect the battery negative cable.
(e) Ignition switch: ON.
(f) Use a multimeter to measure the voltage
between the pin2, 5 of EGR valve connector
E18 and the ground respectively.
Standard voltage
Multimeter connection
Standard value
pin
E18(2)-ground Battery voltage
E18(5)-ground 4.75~5.25 V
Is the inspection result normal?
YES>To step 4.
No > Maintain or replace the harness.
4 . Check EGR valve harness
(a) Ignition switch: OFF.
(b) Disconnect the battery negative cable.
(c) Disconnect the EGR valve connector E18.
(d) Disconnect connector E01 of ECM.
Page 482