DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-431

                 THE ENGINE CAN NOT BE MOTOR JIGGER - (ELECTRIC

                 STARTER MOTOR)

                      Fault phenomenon                  Diagnosis logic                Possible reasons

                                                  • Battery                       • Battery fault
                                                  • Starter or starter circuit    • Starter or starter circuit fault    04
                                                  • Crankshaft                    • Crankshaft fault
                  The engine can not be motor     • Camshaft                      • Camshaft fault
                  jigger - (electric starter motor)
                                                  • Timing mechanism              • Timing mechanism fault
                                                  • Injection timing              • Injection timing fault
                                                  • ECM                           • ECM fault


                 Diagnosis Procedure

                 1 .    Check the engine data

                 (a)    Ignition switch: OFF.
                 (b)    Connect the diagnosis tool with the fault diagnosis connector (16 pins) on the lower
                        left of the dashboard.
                 (c)    Ignition switch: ON, and start the diagnostic tool.
                 (d)    Read the motor data shown on the diagnostic tool.

                 Check whether the data flow is normal or not.
                 YES>To step 2.

                 No >Maintenance related faults.

                 2 .    Check battery
                 (a)    Check whether the battery is in normal status.

                 Is the inspection result normal?
                 YES>To step 3.
                 No >Maintenance related faults.


                 3 .    Check starter and starter circuit
                 (a)    Check whether the starer is damaged.
                 (b)    Check whether the starter circuit is normal.
                 Is the inspection result normal?

                 YES>To step 4.
                 No >Maintenance related faults.


                 4 .    heck the motor machinery
                 (a)    Use an endoscope to observe the in-cylinder condition.
                 (b)    Check engine internal parts, such as crankshaft, camshaft, timing mechanism and so
                        on.

                 Is the inspection result normal?

                 YES>To step 5.